Analysis : 15 - Dog Primary Vacs 123 Vacc. Int. : Set to 52 weeks Other Recall: Interval : Diary : Unavailable
and can set two recalls at one time,
in the example above
only the Type 1 recall (Vaccination) is being set to recall in 52 weeks.
The updating is automatic and transparent to the user e.g. you don't
need to do anything special - use the correct code - thats it.
Stock cards e.g. Program, can also update the recall field. On the Label and Warnings section of the stock card you can enter one recall.
If you want to update multiple recalls from the one code you should
either setup an AP macro or enter the
details in the 'Extras' field.
Recall updates are done with the metacharacters
^2= and ^3=.
| ^1= | Updates Recall 1 (Vaccination) - number of weeks | |
| ^2= | Set's the recall type (1 to 253) You can also add the number of weeks as per: ^2=3.12 for
recall 3 and 12 weeks. This saves having to specify the weeks with ^3.
| |
| ^3= | Set's the interval in weeks for the previous ^2= | |
| e.g. | ||
| ^1=52 | Set vaccination reminder to be recalled in 52 weeks | |
| ^2=4 ^3=26 | Set recall 4 to be recalled in 26 weeks | |
| ^2=4.26 | (same as the above line). | |
If you wish to use an AP code to zero all current recalls for an animal then you can use recall number '253' to set all the intervals on one animal. To remove just one recall then set the number of weeks to '253' for that specific recall.
| Top | Classic | New-Style | Chapters | Sections | Index | Search |