This document contains the technical information required for wiring up an Idex VetTest 8008 to transfer information to a Premvet 5 Unix System.
There are two steps:
a) Edit the file /etc/default/Premvet 5 to include a line :
VETTEST=/dev/tty0a00
Indicating on which port the Vettest is connected.
The file should then look like:
# Main Premvet 5 script to set startup variables # Where are the main data files located VETSYS=/m/vetdata # Location of vet test machine VETTEST=/dev/tty0100
b) Re-boot the system.
The vettest software runs a daemon which runs when the machine starts up. During the re-boot you will see a line
Setting up VetTest link on /dev/tty0a00 PID: 1234
Refer to read218d for the operational instructions.
The connection to the vettest machine should use all the RS232 signals:
DB 25 DB 25 DB9 DB25
2 -- 3 1 -- 8
3 -- 2 2 -- 2
4 -- 5 3 -- 3
5 -- 4 4 -- 6
6 -- 20 5 -- 7
7 -- 7 6 -- 20
20 -- 6 7 -- 5
8 -- 4
You do not need to worry about Baud Rate/Parity or Stop bits these are handled by the monitoring software.
Note: If the VetTest has a VetCom unit attached then the link is via an RJ45 connector on the rear of the VetCom unit. It does not matter which connector is used.
VetCom RJ45 DB9 DB25
1 2 3
2 6 6
3 8 5
4 1 8
5 3 2
6 4 20
7 7 4
8 5 7
Wiring to/from the Stallion Easy I/O boards.
Stallion VetComm DB25 Stallion RJ VetCom RJ45
1 8 1 4
2 4 2 3
3 n/c 3
4 2 4 1
5 3 5 5
6 7 6 8
7 5 7 7
8 20 8 2